<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://wiki.mrrc.pitt.edu/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://wiki.mrrc.pitt.edu/feed.php">
        <title>MRRC Wiki - hardware:eyetracking:eyelink</title>
        <description></description>
        <link>https://wiki.mrrc.pitt.edu/</link>
        <image rdf:resource="https://wiki.mrrc.pitt.edu/lib/exe/fetch.php?media=wiki:dokuwiki.svg" />
       <dc:date>2026-06-05T22:35:48+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:analysis&amp;rev=1743707270&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:calibration&amp;rev=1767796686&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:configuration&amp;rev=1780072376&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:connection&amp;rev=1748464413&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:install&amp;rev=1743707271&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:log&amp;rev=1756403282&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:sensitivity&amp;rev=1751032801&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:task_integration&amp;rev=1761062709&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:taskpc_setup&amp;rev=1748464268&amp;do=diff"/>
                <rdf:li rdf:resource="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:troubleshooting&amp;rev=1743959517&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://wiki.mrrc.pitt.edu/lib/exe/fetch.php?media=wiki:dokuwiki.svg">
        <title>MRRC Wiki</title>
        <link>https://wiki.mrrc.pitt.edu/</link>
        <url>https://wiki.mrrc.pitt.edu/lib/exe/fetch.php?media=wiki:dokuwiki.svg</url>
    </image>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:analysis&amp;rev=1743707270&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-04-03T19:07:50+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Analysis</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:analysis&amp;rev=1743707270&amp;do=diff</link>
        <description>EyeLink Analysis

Reading EDF

The tracker writes .edf files containing samples, messages, and events

There are various tools to read these files.

	*  matlab: edfmex tool
	*  R: eyelinkReader
	*  python: eyelinkio or pyedfread
	*  to ascii for universal reading: edf2asc in developer SDK (linux)

Matching saccades to task events

example R code -</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:calibration&amp;rev=1767796686&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-01-07T14:38:06+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>SR Research EyeLink Calibration</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:calibration&amp;rev=1767796686&amp;do=diff</link>
        <description>SR Research EyeLink Calibration

This page documents calibration steps after finishing camera and PC setup

Calibration Software

Run control64.exe on the task PC. This will display calibration points to the participant and talk to the EyeLink Host PC.  The EyeLink SDK installs this to</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:configuration&amp;rev=1780072376&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-05-29T16:32:56+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Camera Configuration</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:configuration&amp;rev=1780072376&amp;do=diff</link>
        <description>EyeLink Camera Configuration

The Host PC&#039;s PHYSICAL.INI (read-only) and the overwriting FINAL.INI record distance and screen measurements  used in eye gaze modeling and degrees of visual angle calculation.

[2026-05-29: retrieved PHYSICAL.INI and FINAL.INI from P1 and P2]</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:connection&amp;rev=1748464413&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-05-28T20:33:33+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Ethernet Connection</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:connection&amp;rev=1748464413&amp;do=diff</link>
        <description>EyeLink Ethernet Connection

The EyeLink Ethernet port is reported (Aug 2020) to be &quot;full&quot; gigabit&quot; ⩵ 1000Mbps. 

The EyeLink host defaults to 100.1.1.1. This can be changed but is assumed in many of EyeLink&#039;s tools. Because the P1 and P2 control room task PCs already interface with</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:install&amp;rev=1743707271&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-04-03T19:07:51+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>SR Research EyeLink Install</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:install&amp;rev=1743707271&amp;do=diff</link>
        <description>SR Research EyeLink Install

Useful videos include

	*  Siemens Tray Mount setup
	*  Eye Tracker Positioning (illuminator) video.
	*  Participant Setup/Positioning

Tray positioning

from EyeLink® 1000 Plus Installation Guide: Long Range Mounts (pg 63)

	&quot; For use with the 32 channel Siemens head coil (monocular only) the post needs to be displaced to the side of the eye-to-be-tracked... Note that placement of the</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:log&amp;rev=1756403282&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-08-28T17:48:02+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Log</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:log&amp;rev=1756403282&amp;do=diff</link>
        <description>EyeLink Log

Notable events for the SR eye trackers.
 date        scanner  event  2025-08-27  P2/32ch  surface-first mirror tape failed. fell out  2025-??-??  ??       surface-first mirror adhesive fully extended across back   2024-09-05  P1 + P2  installed surface-first mirrors</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:sensitivity&amp;rev=1751032801&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-06-27T14:00:01+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>Eyelink Saccade Sensitivity</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:sensitivity&amp;rev=1751032801&amp;do=diff</link>
        <description>Eyelink Saccade Sensitivity

The default “Normal” sensitivity is likely appropriate for the noisier long-range-optic MR recording.



	&quot; 2.4.1.2 Camera Setup Screen Main Functions
 [saccade sensitivity setup toggle image]
 Define the sensitivity of the EyeLink 1000 Plus parser for saccade event generation. Normal is intended for cognitive tasks like reading; while High is intended for psychophysical tasks where small saccades must be detected. See Section 4.3.3 Saccadic Thresholds for details of…</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:task_integration&amp;rev=1761062709&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-10-21T16:05:09+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Task Integration</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:task_integration&amp;rev=1761062709&amp;do=diff</link>
        <description>EyeLink Task Integration

This page describes how to interact with the EyeLink Tracker from your task/code -- start, stop, annotate with triggers, messages. The analysis page has tips for the next step: exploring the collected edf file data offline.

Jump to  for example code.</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:taskpc_setup&amp;rev=1748464268&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-05-28T20:31:08+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Task Computer Setup</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:taskpc_setup&amp;rev=1748464268&amp;do=diff</link>
        <description>EyeLink Task Computer Setup

This page outlines steps needed to setup SR Research EyeLink 1000 Plus for in-scanner eye tracking. Also see the SR Research participant setup video .

A nascent (2025-04-03) checklist document is on here

Once the camera and task PC are setup, you likely want to run SR Research EyeLink Calibration. 

Other eye tracking topics include</description>
    </item>
    <item rdf:about="https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:troubleshooting&amp;rev=1743959517&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2025-04-06T17:11:57+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>EyeLink Troubleshooting</title>
        <link>https://wiki.mrrc.pitt.edu/doku.php?id=hardware:eyetracking:eyelink:troubleshooting&amp;rev=1743959517&amp;do=diff</link>
        <description>EyeLink Troubleshooting

Cannot find SCD File



BAC66200.SCD
 Scanner  Camera config Prisma2 ZCB07140.SCD Prisma1  ZCA41140.SCD 
Connection Error</description>
    </item>
</rdf:RDF>
